Electric infrared heating systems · Floor, wall and ceiling
Heat the room,not the air in it.
Lamina Heat designs, manufactures and supports carbon-fibre electric infrared heating systems that disappear into the floors, walls and ceilings of the finest homes and buildings. Heating elements from 0.4 to 1.4 mm thick. Once the finish goes on, you will never see it again.
Full-surface far infrared heating · 100% of the installed area30–50% less energy than wire or wet systemsAdds 2 mm to 5 cm to the build-up20+ year third-party tested lifespan
One element, three surfaces
Infrared heating designed to suit each individual space.
The same carbon-fibre element goes under the floor, behind the plaster, or into the ceiling. Which one is a question of what suits you and the room best, not of what the system can do. We work with you to identify the best solution for your space.
Every conventional system heats a room from the outside in.
A radiator, a heat pump or a warm-air unit warms air, then waits for that air to carry the heat to you. Hot air rises, stratifies at the ceiling and leaves the moment a door opens. Radiant heating skips the carrier: energy travels as far-infrared, is absorbed by surfaces and people, and warms them directly. It is the most natural way to be warm, the same mechanism as the sun, and because nothing is wasted heating air you will never occupy, it is both more comfortable and more energy efficient than any system that moves heat around on air or water.
Under 2 °CAnkle to head
40–60%Relative humidity
3–10 minTo felt warmth
Radiant: the surfaces of the room are the heating
The whole floor, wall or ceiling emits far-infrared at a low surface temperature. Energy is absorbed by you and by the room's surfaces directly, so comfort holds when a door opens and the air is never heated hard enough to dry it out. Nothing is ducted or vented, and floor, wall and PowerBoard 250 systems are invisible once finished.
Air movement and dust
None
Loss when a door opens
Surfaces stay warm
Equipment in the room
None, except surface-mounted panels
Annual maintenance
None
The wavelength
Our surfaces emit long-wave infrared at 6 to 15 µm, the same band your own body radiates at. It is absorbed at the skin rather than passing into it, it cannot be seen, and it warms the room's surfaces as readily as it warms you.
We are not a film company. We supply the whole heating system.
From heat-loss calculation to commissioning records. Your trades install it. Our engineering stands behind it.
01
CAD design
Room-by-room heat loss, element layout drawings and load schedules, prepared from your plans.
02
Material preparation and delivery
Heaters made to length and pre-cabled to the drawing, labelled per room and shipped as a kit with connectors and thermostats.
03
Installation
Heaters laid out to the design plan by your own trades and cabled together, with remote support on the first projects.
04
Post-installation commissioning
Resistance and insulation tests, thermal imaging of every zone, and commissioning records for handover.
Design
Heat load and layout
Send us plans and a construction spec. We return a room-by-room heat loss calculation, element layout drawings, circuit and load schedules, and the electrical design your contractor builds from.
Manufacture
Elements prepared to your room design
Carbon-fibre elements prepared and pre-cabled to your room design, from 600 to 900 mm wide and in variable lengths depending on the product type. No additional wiring and no manipulation of the films is required on site.
Control
Zoning and thermostats
Thermostats, sensors and zone logic specified with the system, so a fast-responding surface is actually run fast. Low-voltage systems run on the LaminaHeat Multi Zone Power Supply: up to five independently controlled zones per unit, up to 6000 W, 110–240 V in and 12–48 V out, with a PV or battery DC input.
Support
Installer support and sign-off
Method statements for your trades, a pre-cover inspection checklist, remote support during the install, and commissioning records for handover. Your electrician and your plasterer fit it.
Warranty
Certification and warranty
CE and UKCA marked across the range, BEAB tested to IEC 60335-1, with SafeTech EGS additionally UL listed. ISO 9001 manufacturing, a 10-year product warranty and a tested 20+ year service life with under 3% output degradation.
The material
At the core of every system: a carbon-fibre element.
Carbon fibre is what lets a heating element be full-surface, from 0.4 to 1.4 mm thick, fully grounded and safe enough to bury in a wall for the life of the building. It is why we can size the element to the room instead of picking one from a shelf.
ComfortScrim · 0.4 mm, perforated so plaster keys straight through itSafeTech EGS · 1.4 mm, encapsulated and pre-cabled for the floor
0.4 to 1.4 mm thick
The element disappears into plaster, adhesive or screed.
Robust
Tensile strength several times that of steel at a fifth of the density.
Fire resistant
Carbon fibre tolerates temperatures far beyond anything a building sees.
Water immersion tested
Zero moisture absorption. Tested submerged as part of SafeTech.
Fully grounded
A grounded full-surface element, not a wire on a spacing.
PV compatible
The 48 V system connects straight to solar or a battery, with no inverter in between.
Built and running
Recent projects.
Wall system
Old winery, Detzem, Germany
A three-storey house hand-built in 1950 and heated by a wood-fired oven ever since. ComfortScrim went into the walls of the 36 m² living and dining room, 15.6 linear metres of 600 mm film on a 3200 VA supply, and was plastered straight over.
25 working hours · two days
Ceiling system
Home retrofit, England
PowerBoard panels surface-mounted to the existing ceilings of an occupied English home. No construction work, no floors lifted and no walls disturbed.
Surface-mounted panels
Floor system
Open-plan office, Jinan
SafeTech EGS heaters set out wall to wall across a large office floor and daisy-chained with plug-and-play connectors before the finish went down. No plant room, no manifolds.
Plug-and-play heaters
“We do not need hot air to feel comfortable.”
Reiner Duchene · ComfortScrim · old winery, Detzem, Germany
Certified and tested
IEC 60335-1BEAB approved
UL E526594UL listed
ISO 9001Quality management
CEEU conformity
UKCAUK conformity assessed
TÜVType tested
The element range
The hardware behind the systems.
If you are specifying rather than buying a system, this is the range. We will still do the layout and the load schedule.
Element
Voltage
Surfaces
Embedded in
Specified when
ComfortScrim
12–48 V DC
Floor, wall, ceiling
Plasters, adhesives, levelling compounds
Invisible comfort heat is wanted in walls and ceilings, and ceilings are under three metres
SafeTech EGS
110–240 V AC
Floor
Under floating, dry and embedded floor finishes
Warm feet are wanted, or ceilings exceed three metres
PowerBoard 250
110–240 V AC
Ceiling
Plasterboard grid, 1200 × 600 mm
A suspended plasterboard ceiling is being installed
PowerBoard 500 / 750
110–240 V AC
Ceiling, surface-mounted
Nothing, mounted panel
No large construction is allowed and fast mounting is required, with ceilings under 3.5 metres
We support distributors with installation training, marketing material, sales engineering and a direct line to our design team. Tell us where you are and what you sell today.
The same element heats vehicle interiors, wearables, bridge decks and driveways. We supply it cut and terminated to your assembly, from 5 to 3000 W/m² and 5 to 680 V.